فیلترها/جستجو در نتایج    

فیلترها

سال

بانک‌ها



گروه تخصصی







متن کامل


اطلاعات دوره: 
  • سال: 

    2013
  • دوره: 

    9
  • شماره: 

    2
  • صفحات: 

    107-116
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    298
  • دانلود: 

    0
چکیده: 

In this paper, the effect of Static VAr Compensator (SVC) parameters on the nonlinear interaction of steam power plant turbine-generator set is studied using the Modal Series (MS) and Normal Form (NF) methods. A second order representation of a power system equipped with SVC is developed. Then by MS and NF methods, the nonlinear interaction of torsional modes is assessed under various conditions and the most influencing factors are determined. Furthermore, to better analysis the nonlinear interaction between torsional modes and SVC controllers new nonlinear interaction index is defined. The results show that the stress conditions and some SVC control parameters will adversely affect the dynamic performance of a power system by increasing the nonlinear interaction of torsional modes. In this situation, the nonlinear modal analysis techniques especially MS method can precisely provide a reliable prediction of the torsional oscillations amplitudes and the frequency content of the output system response. As the angle and speed of turbine generator segments are used as input signals in several controllers, the frequency content of these signals are quite important in designing such controllers. This analysis is performed on a 4-areas WSCC system, which is equipped with a SVC.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 298

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2018
  • دوره: 

    11
  • شماره: 

    2
  • صفحات: 

    331-342
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    225
  • دانلود: 

    0
چکیده: 

Shock vectoring control (SVC) is an important method of fluidic thrust vectoring (FTV) for aero-engine exhaust system. It behaves better on nozzle of high pressure ratio, and is considered as an alternative TV technology for a future aero-engine with high thrust-to-weight ratio. In this paper, the flow mechanism and vector performance, including the vector angle (δ p) and thrust coefficient (Cfg), of 2D and axisymmetric SVC nozzles were investigated after the validation of turbulence models by experimental data. The influence of aerodynamic parameters, e. g. nozzle pressure ratio (NPR), secondary pressure ratio (SPR) and free-stream Ma number (M∞ ) on flow characteristics and vector performance were studied numerically, and results show that unbalanced pressure distributions on nozzle internal walls determine δ p, while shock waves dominate thrust loss, referring to Cfg. The “ pressure release mechanism” of an axisymmetric SVC nozzle causes vector angle about 16. 54% smaller than that of a 2D SVC nozzle at NPR of 6. The induced shock wave interacts with nozzle upper wall at SPR of 1. 5, and results in the δ p of a 2D SVC nozzle 12% smaller. A new parameter (Fy, modi) of side-force was redefined for free-stream conditions, taking the pressure distributions on nozzle external walls into account. Results indicate that pressure connection on nozzle external walls of an axisymmetric SVC nozzle causes vector performance better at M∞ >0. 3 and the δ p is about 11. 2% larger at transonic conditions of M∞ of 0. 9 and 1. 1.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 225

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2008
  • دوره: 

    -
  • شماره: 

    -
  • صفحات: 

    0-0
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    172
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 172

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    8
  • شماره: 

    3
  • صفحات: 

    260-262
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    84
  • دانلود: 

    0
چکیده: 

Superior vena cava (SVC) syndrome, a potentially life threatening medical emergency, occurs due to SVC obstruction caused by extrinsic compression, intrinsic stenosis or thrombosis. Malignant mediastinal tumours account for more than 80% of cases of SVC syndrome. We hereby report a case of SVC syndrome who came with clinical features suggestive of SVC syndrome with dyspnea managed and diagnosed in the Intensive Care Unit with a multidisciplinary approach.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 84

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1388
  • دوره: 

    -
  • شماره: 

    34 (ویژه نامه مهندسی برق)
  • صفحات: 

    61-76
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1172
  • دانلود: 

    244
چکیده: 

در این مقاله، بازیابی سیستمهای قدرت مجهز به ادوات SVC و TCSC در صورت بروز قطعیهای جزیی مورد مطالعه قرار گرفته و روشی جدید برای تامین حداکثر بار با استفاده از ترکیبهای مختلف متغیرهای کنترلی ارایه شده است. این متغیرها شامل تپ ترانسفورمرهای قدرت، برنامه ریزی مجدد واحدهای تولیدی و تعیین نقاط کار ادوات کنترلی FACTS موجود در شبکه می شود. تابع هدف، حداکثر کردن مقدار بار بازیابی شده است و قیود مختلف بهره برداری، شامل دامنه ولتاژ شینه ها، مقدار توان عبوری از خطوط انتقال و محدوده تولید واحدها در فرایند بهینه سازی و تعیین پاسخ نهایی ملحوظ شده است. همچنین در حالت خروج یک خط انتقال، به منظور جلوگیری از ایجاد شرایط گذرای شدید و جابه جایی توانهای زیاد در شبکه، شرط قرار گرفتن تفاضل زاویه استاتیکی (SPA) ولتاژ دو طرف کلید در محدوده مجاز، در تعیین پاسخ نهایی مد نظر قرار گرفته است. با توجه به تعدد متغیرهای کنترلی، بهینه سازی به کمک الگوریتم ژنتیک انجام شده و سیستم IEEE-118bus به عنوان شبکه تست برای ارزیابی قابلیتهای روش پیشنهادی مورد استفاده قرار گرفته که نتایج شبیه سازیها در بخش مطالعات عددی آورده شده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1172

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 244 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2006
  • دوره: 

    -
  • شماره: 

    -
  • صفحات: 

    1-5
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    130
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 130

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    2013
  • دوره: 

    7
  • شماره: 

    4 (27)
  • صفحات: 

    17-26
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    318
  • دانلود: 

    0
چکیده: 

There are relatively few literatures about Flexible AC Transmission Systems (FACTS) in reliability aspects, particularly in composite system reliability evaluation. Reliability of the power system could be studied by some indices that help to compare power system under different conditions from reliability point of view. The actual benefits of the FACTS can be quantitatively estimated using suitable models and techniques. Corrective control as an alternative for the system reinforcement is proposed in this paper as a suitable way to ease the challenges related to building new transmission lines or reconstruction of power grid. Static Var Compensator (SVC) as a member of FACTS family has been used as corrective control. A test case with three scenarios is considered for comparing the effect of SVC on the reliability of the power system. It will be seen that the correct SVC replacement has a great influence on the reliability indices of power grid and losses could be diminished.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 318

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

دائمی غزل

اطلاعات دوره: 
  • سال: 

    1403
  • دوره: 

    9
  • شماره: 

    2
  • صفحات: 

    88-99
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    32
  • دانلود: 

    6
چکیده: 

هر سیستم های قدرت برق را از مراکز تولید به نقاط مختلف مصرف در مسافت های طولانی منتقل می کنند. این امر در حالی است که در گذشته، توزیع برق در محدوده های کوچک و با ولتاژ پایین انجام می گرفت. تبادل توان در سطوح ولتاژ بالا مزایایی مانند به اشتراک گذاری و ایجاد رقابت را به همراه دارد. پایداری ولتاژ در این سیستم ها از اهمیت بالایی برخوردار است. ناپایداری ولتاژ زمانی رخ می دهد که با افزایش بار، ولتاژ سیستم به طور قابل توجهی افت کند و به سطحی غیرقابل قبول برسد. و منجر به خاموشی، آسیب به تجهیزات و سایر مشکلات شد. اگر منابع تغذیه کننده سیستم محدودیت داشته باشند، احتمال ناپایداری ولتاژ افزایش می یابد. محدودیت می تواند به دلیل کمبود توان یا توان راکتیو باشد. اگر بار به طور ناگهانی افزایش یابد، سیستم ممکن است فرصت کافی برای تنظیم ولتاژ را نداشته باشد و ناپایدار شود. خرابی در خطوط انتقال یا ژنراتورها می تواند منجر به افت ولتاژ و ناپایداری شود. اگر سیستم های کنترل ولتاژ به درستی کار نکنند، ممکن است نتوانند افت ولتاژ را به طور موثر جبران کنند و سیستم ناپایدار شود. با افزایش ظرفیت منابع تولید و انتقال، می توان از محدودیت منابع و ناپایداری ولتاژ جلوگیری کرد. سیستم های کنترل ولتاژ می توانند به طور خودکار ولتاژ را در سطح قابل قبولی حفظ کنند. با طراحی صحیح سیستم قدرت، می توان احتمال ناپایداری ولتاژ را کاهش داد. ناپایداری ولتاژ می تواند منجر به مشکلات مختلفی شود. درک عوامل مؤثر بر ناپایداری ولتاژ و انجام اقدامات پیشگیرانه، می توان از بروز این پدیده جلوگیری کرد و پایداری ولتاژ را در سیستم های قدرت برقرار کرد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 32

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 6 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

SOLTANI J. | FATHABADI A.M.

اطلاعات دوره: 
  • سال: 

    2003
  • دوره: 

    16
  • شماره: 

    3 (TRANSACTIONS B: APPLICATION)
  • صفحات: 

    235-246
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    457
  • دانلود: 

    0
چکیده: 

This paper describes the application of static var compensators, (SVC) on an electrical ‎distribution network containing two large synchronous motors, one of which is ‎excited via a three-phase thyristor bridge rectifier. The second machine is excited via ‎a diode bridge rectifier. Based on linear optimization control (LOC), the measurable ‎feedback signals are applied to the control system loops of SVC and the excitation ‎control loop of the first synchronous motor. The phase equations method was used to ‎develop a computer program to model the distribution network. Computer results ‎were obtained to demonstrate the system performance for some abnormal modes of ‎operation. These results show that employing SVC based on the LOC design for ‎electrical distribution networks containing large synchronous motors is beneficial and ‎may be considered a first stage of the system design‏.‏

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 457

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

SOLTANI J. | FATHABADI A.M.

نشریه: 

VIRTUAL

اطلاعات دوره: 
  • سال: 

    621
  • دوره: 

    1
  • شماره: 

    1
  • صفحات: 

    235-246
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    148
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

This paper describes the application of static var compensators, (SVC) on an electrical distribution network containing two large synchronous motors, one of which is excited via a three phase thyristor bridge rectifier. The second machine is excited via a diode bridge rectifier. Based on linear optimization control (LOC), the measurable feedback signals are applied to the control system loops of SVC and the excitation control loop of the first synchronous motor. The phase equations method was used to develop a computer program to model the distribution network. Computer results were obtained to demonstrate the system performance for some abnormal modes of operation. These results show that employing SVC based on the LOC design for electrical distribution networks containing large synchronous motors is beneficial and may be considered a first stage of the system design

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 148

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button